What does the E-ABI measure?
E-ABI measures UV Index (UVI), UVA intensity and UVB intensity at the measurement position. It is designed primarily for reptile UVB lamp and basking-zone checks.
See UVI, UVA & UVB. Know what your lamp delivers at the basking zone.
E-ABI helps reptile keepers check UVB lamp output at the actual basking zone — not by guessing from brightness, but by measuring UVI plus separate UVA and UVB intensity.
EvoDevice E-ABI is a handheld reptile UV meter designed for checking UV conditions at reptile basking zones. It measures UV Index (UVI), UVA intensity and UVB intensity, supports HOLD for freezing the current reading, and can record and review up to 33 measurement points for comparing lamp distance and position.
E-ABI measures UVA from 0–29,000 μW/cm² and UVB from 0–70,000 μW/cm², with switchable UV intensity units of μW/cm², W/m² and mW/cm². Its UVA function is calibrated using a 365 nm LED source and is not positioned as a UVC / 254 nm measurement instrument.
A UVB lamp label tells you what the lamp is designed to produce. E-ABI helps you check what reaches the measurement point inside the actual setup.
Measure at the basking area, compare another position, or repeat the same test later to monitor changes in lamp output.
Each measurement point is stored as one screen. Measure another location, save it, and continue through your setup.
Useful for comparing basking areas, lamp distances, different positions, or repeating the same measurement pattern later.
Dedicated physical controls make it easy to measure, switch functions, hold a reading and record a test point.
UVI is a weighted UV Index. UVA and UVB are radiation intensity measurements.
UVI is a weighted UV Index rather than a simple UVA + UVB total. UVB contributes much more strongly to the UVI value than UVA.
E-ABI provides both the easy-to-read UVI value and separate UVA / UVB intensity information from the same measurement position.
UVI, UVA intensity and UVB intensity describe different aspects of the same UV environment. E-ABI shows all three at the measurement position so you can compare basking locations without treating the values as interchangeable.
The EvoDevice Light & UV Measurement Guide explains how UVI, UVA and UVB differ from visible-light measurements such as Lux and CCT. Read the Light & UV Measurement Guide →
Built for practical UV lamp testing across a wide range of output levels.
Know what the UVA measurement is calibrated for and choose the UV intensity unit you prefer.
For best UVA measurement results, use the UVA function with 365nm LED sources. It is not recommended as a reference measurement for 385–405nm LEDs.
Display UVA and UVB radiation intensity in μW/cm², W/m² or mW/cm².
E-ABI's UVA function is calibrated using a 365nm LED source. For best results, use this function for measuring 365nm LED sources. Measurements of 385–405nm LEDs should not be treated as equivalent reference measurements.
Choose the instrument based on the UV source and the measurement task.
Check UVI and separate UVA / UVB intensity from reptile UVB lamps, compare basking positions, test different distances, record multiple measurement points and repeat the same checks later.
E-ABI is designed around UVI, UVA and UVB measurement. It is not positioned as a UVC / 254nm measurement instrument.
Quick answers about what E-ABI measures, how its recorded points work, and the intended scope of its UVA, UVB and UVI functions.
E-ABI measures UV Index (UVI), UVA intensity and UVB intensity at the measurement position. It is designed primarily for reptile UVB lamp and basking-zone checks.
Yes. Measure at the actual basking zone, then repeat the measurement at different positions or distances to compare how UV conditions change across the setup.
E-ABI can record and review up to 33 measurement points, allowing you to compare multiple locations or repeat the same measurement pattern later.
The stated UVA measurement range is 0–29,000 μW/cm² and the stated UVB measurement range is 0–70,000 μW/cm².
UVA and UVB intensity can be displayed in μW/cm², W/m² or mW/cm².
The UVA function is calibrated using a 365 nm LED source. Measurements of 385–405 nm LEDs should not be treated as equivalent reference measurements.
No. E-ABI is designed around UVI, UVA and UVB measurement and is not positioned as a UVC / 254 nm measurement instrument.
E-ABI focuses on reptile UV lamp measurement with UVI plus separate UVA and UVB intensity readings. For a broader view, learn how UV measurements differ from visible-light measurements such as Lux, CCT and white LED spectral distribution.
Measure UVI, UVA and UVB, compare different locations, and save up to 33 measurement points with E-ABI.
View Purchase OptionsUVI, UVA and UVB describe different aspects of ultraviolet exposure. Review their definitions before interpreting UV measurements at a reptile basking zone or other UV measurement location.
Choose E-ABI for UVI, UVA and UVB measurement, including reptile basking-zone checks. Choose E130 when you need Lux, CCT and supported white-LED spectral-distribution measurement.